The air-tight detector completes the testing for sealing performance o f accumulator on the basis of principle of
breakdown by high voltage, which boasts the features of simple operation and fast testing and so on. specialty:
The discharging current, the voltage, the time size may adjust, automatically demonsto rated the voltage, the
magnitude of current, also the unqualified battery acousto-optics reports to the police. Notice: 1.after the high-voltage electrode has been pressed down, the high-voltage electrode column shall be ensured not
go beyond its limit of elasticity; the space between the high-voltage cover and the battery shall be set properly.
The testing will not be precise if the space is too large; or it is hard to position the battery.
2. Lubricant should be added to the guide column frequently to ensure the smooth sliding.
3. No corrosive liquids such as vitriol shall be poured or splashed on the detector or worktable. The worktable, roller